6AG4010-*A22-0XX5
SIMATIC IPC3000 SMART V2 (機架式 PC,19",4 個高度單位); 奔騰雙核處理器 G3260 (2C/2T,3.3 GHz,3MB 緩存); 500 GByte 硬盤 SATA,內部; 4 GB DDR3 SD-RAM (1x 4 GB),雙通道; DVD +/-RW; 接口:2個 Gbit LAN; 2個串行: 2個 COM2(RS-232/422/485); 背面 4個 USB; 2x 正面 USB; 1個 VGA;1個 DVI-D; 2x PS/2;音頻; 無操作系統(tǒng);
_______________________
【SIEMENS】
上海西熙工控自動化有限公司
聯(lián)系人:徐工
手 機:13681636331
Q Q:1197371023
座 機:0573-84882821
________________________________
上海西熙工控自動化有限公司是一家專業(yè)從事西門子工業(yè)自動化產品和數(shù)控系統(tǒng)銷售、技術服務及培訓的工程服務公司。
銷售代理西門子WINCC組態(tài)軟件,西門子PLC編程軟件,西門子PLC,S7-200CN/S7-200/S7-300/S7-400/S7-1200/(6ES7/6GK/6AV/6FC/6SN/6FX/6SE/6RA/6DD/7ML/7MH/7KM/7MF/3RV/3RH/3TF)西門子PROFIBUS-DP總線,RS485總線接頭,CP網卡,變頻器,觸摸屏,低壓電器,數(shù)控伺服備件。
概述
SIMATIC IPC3000 SMART V2 (Rack PC, 19", 4HU); Pentium Dual Core G3260 (2C/2T, 3.3 GHz, 3 MB cache); 500 GB HDD SATA, internal; 4 GB DDR3 SD-RAM (1x 4 GB), Dual channel; DVD +/-RW; Interfaces: 2x Gbit LAN; 2x serial: 2x COM2 (RS232/422/485); 4x USB on the rear side; 2x USB on the front; 1x VGA; 1x DVI-D; 2x PS/2; audio; without operating system; device is only for released for Chinese market!
Installation type/mounting
Mounting For horizontal and vertical mounting
Design Rack PC, 19", 4U
Rack mounting Yes
Supply voltage
Type of supply voltage 220 V AC
Line frequency
● Rated value 50 Hz Yes
● Rated value 60 Hz Yes
Processor
Processor type Intel Pentium G3260, Intel Core i5-4570s
Chipset Intel H81
Drives
Optical drives DVD-RW
Hard disk Pre-install 500 GB or 1 TB HDD
Memory
Type of memory Dual channel DDR3 1333 / 1600 MHz
Main memory 2 GB (pre-installed), support up to 16 GB
Capacity of main memory, max. 16 Gbyte
Hardware configuration
Slots
● free slots 4x PCI, 1x PCIe (x1), 1x PCIe (x8) (2 Lanes), 1x PCIe (x16) (16 Lanes)
Interfaces
USB port 2x USB 3.0 rear, 2x USB 2.0 rear, 2x USB 2.0 front, 1x USB 2.0 internal
Connection for keyboard/mouse 2x PS/2
serial interface 2x COM ports (RS 232, RS 422, RS 485)
Multimedia
● Audio In/Out Yes
● Microphone In Yes
Video interfaces
● Graphics interface 1x VGA; 1x DVI-D
Industrial Ethernet
● Industrial Ethernet interface
— 100 Mbps Yes
— 1000 Mbps Yes
Integrated Functions
Monitoring functions
● Status LEDs POWER, HDD
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of static electricity ±4 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2
Interference immunity against high-frequency electromagnetic fields
● Interference immunity against high frequency radiation 10 V/m for 80 - 1 000 MHz, 80% AM acc. to IEC 61000-4-3; 3 V/m for 1.4 - 2 GHz, 80% AM acc. to IEC 61000-4-3; 1 V/m for 2 - 2.7 GHz, 80% AM acc. to IEC 61000-4-3; 10 V for 150 kHz - 80 MHz, 80% AM acc. to IEC 61000-4-6
Interference immunity to cable-borne interference
● Interference immunity on supply cables ±2 kV acc. to IEC 61000-4-4, burst; ±1 kV acc. to IEC 61000-4-5, surge symmetric; ±2 kV acc. to IEC 61000-4-5, surge asymmetric
● Interference immunity on signal cables >30m ±2 kV acc. to IEC 61000-4-4, burst; length > 30 m; ±2 kV acc. to IEC 61000-4-5, surge; length > 30 m
● Interference immunity on signal cables < 30m ±1 kV acc. to IEC 61000-4-4, Burst
Interference immunity against voltage surge
● asymmetric interference ±2 kV acc. to IEC 61000-4-5, surge asymmetric
● symmetric interference ±1 kV acc. to IEC 61000-4-5, surge symmetric
Interference immunity to magnetic fields
● Interference immunity to magnetic fields at 50 Hz 30 A/m; to IEC 61000-4-8
Emission of conducted and non-conducted interference
● Interference emission via line/AC current cables IEC 61000-6-4, CISPR 22, FCC Class A
Compliance with line harmonic distortion limits
● Compliance with line harmonic distortion acc. to IEC 61000-3-2, IEC 61000-3-3 Yes; EN 61000-3-2 Class D; EN 61000-3-3
Degree and class of protection
IP (at the front) 20
IP (rear) IP20
Ambient conditions
Ambient temperature during operation
● Ambient temperature during operation +5 °C to +40 °C
Relative humidity
● Relative humidity Tested according to IEC 60068-2-78, IEC 60068-2-30: 5% to 80% at 25 °C (no condensation)
Vibrations
● Vibration resistance during operation acc. to IEC 60068-2-6 IEC 60068-2-6; 10 Hz to 58 Hz 0.015 mm; 58 Hz to 200Hz 1.96 m/s2
Shock testing
● Shock load during operation IEC 60068-2-27; half-sine 9.8 m/s2, 20 ms, 3 shocks pre axis
Operating systems
without operating system Yes
pre-installed operating system
● Windows 7 No
Dimensions
Width 430 mm
Height 177 mm
Depth 463 mm
西門子6AG4010-*A22-0XX5工控機
資訊來源:上海西熙工控自動化有限公司
|